Product Overview - Domestic
Domestic products (listed below) are available in the United States and Canada.
International products are available outside the United States and Canada. Click here to view international products or the international product overview.
|
INSTALLER
FRIENDLY
SERIES® |
APPLICATION |
PUMP VOLTAGE RATING |
FULL LOAD AMPS |
PUMPING RANGE |
FLOATS INCLUDED |
|
IFS 1-Phase Simplex Demand/TD |
Indoor/outdoor simplex (demand/TD)
control system |
120/208/240 VAC |
Up to 20 FLA |
Depends upon application |
Sensor Float® control switches |
|
IFS 1-Phase Duplex Demand/TD |
Indoor/outdoor duplex (demand/TD)
control system |
120/208/240 VAC |
Up to 20 FLA |
Depends upon application |
Sensor Float® control switches |
| IFS 3-Phase Simplex Demand |
Indoor/outdoor simplex (demand)
control system |
208/240/480 VAC |
Up to 25 FLA |
Distance between
start & stop float |
Sensor Float® control switches |
| IFS 3-Phase Duplex Demand |
Indoor/outdoor duplex (demand)
control system |
208/240/480 VAC |
Up to 25 FLA |
Distance between
start & stop float |
Sensor Float® control switches |
| IFS Simplex Capacitor |
Indoor/outdoor simplex capacitor start/run
control system |
120/208/240 VAC |
Up to 40 FLA |
Distance between
start & stop float |
Sensor Float® control switches |
| IFS Duplex Capacitor |
Indoor/outdoor duplex capacitor start/run
control system |
120/208/240 VAC |
Up to 40 FLA |
Distance between
start & stop float |
Sensor Float® control switches |
|
| |
|
| SINGLE PHASE SIMPLEX |
APPLICATION |
PUMP VOLTAGE RATING |
FULL LOAD AMPS |
PUMPING RANGE |
FLOATS INCLUDED |
|
Model 111 |
Indoor/outdoor simplex
control system |
120 VAC or
120/208/240 VAC |
Up to 20 FLA |
Distance between start & stop float or
range of pump switch |
Two Sensor Float® control switches or
one pump switch
(mounting clamp version) |
|
Model 115 |
Indoor/outdoor simplex
control/alarm system
120 VAC alarm circuit |
120 VAC or
120/208/240 VAC |
Up to 15 FLA |
Range of
pump switch |
One Sensor Float® control switch and
one pump switch
(mounting clamp version) |
|
Model 112 |
Indoor/outdoor simplex
control/alarm system
120 VAC control/alarm circuit |
120 VAC or
120/208/240 VAC |
Up to 30 FLA |
Distance between
start & stop float |
Three Sensor Float® control switches
(mounting clamp version) |
|
| |
| SINGLE PHASE DUPLEX |
APPLICATION |
PUMP VOLTAGE RATING |
FULL LOAD AMPS |
PUMPING RANGE |
FLOATS INCLUDED |
|
Model 122 |
Indoor/outdoor duplex alternating
control/alarm system 120 VAC control/alarm circuit. |
120 VAC or
120/208/240 VAC |
Up to 30 FLA |
Distance between
start & stop float |
Three or four Sensor Float® control
switches
(mounting clamp version) |
|
| |
| THREE PHASE SIMPLEX |
APPLICATION |
PUMP VOLTAGE RATING |
FULL LOAD AMPS |
PUMPING RANGE |
FLOATS INCLUDED |
Model 312
Includes adjustable overload protection, branch circuit
protection, pump disconnect, and 120 VAC control transformer |
Indoor/outdoor
three phase simplex
control/alarm system
120 VAC control circuit |
Consult Factory
for application
specifications |
Up to 25 FLA |
Distance between
start & stop float |
Three Sensor Float®
control switches
(mounting clamp version) |
|
| |
| THREE PHASE DUPLEX |
APPLICATION |
PUMP VOLTAGE RATING |
FULL LOAD AMPS |
PUMPING RANGE |
FLOATS INCLUDED |
Model 322
Includes adjustable overload protection, branch circuit, pump
disconnect, and 120 VAC control transformer |
Indoor/outdoor three phase duplex
alternating
control/alarm system
120 VAC control circuit |
Consult Factory
for application
specifications |
Up to 25 FLA |
Distance between
start & stop float |
Three or four Sensor Float® control
switches
(mounting clamp version) |
|
| |
| CAPACITOR START/RUN |
APPLICATION |
PUMP VOLTAGE RATING |
FULL LOAD AMPS |
PUMPING RANGE |
FLOATS INCLUDED |
Model SGS
Call Factory for capacitor kit option code and pricing |
Indoor/outdoor
single phase simplex
control/alarm system 120 VAC control/alarm circuit |
120 VAC or
120/208/240 VAC |
Up to 20 FLA |
Distance between
start & stop float |
Three Sensor Float® control switches
(mounting clamp version) |
Model 113
Call Factory for capacitor kit option code and pricing |
Indoor/outdoor simplex
control/alarm system
120 VAC control/alarm circuit |
120 VAC or
120/208/240 VAC |
Up to 40 FLA |
Distance between
start & stop float |
Three Sensor Float® control switches
(mounting clamp version) |
Model 123
Call Factory for capacitor kit option code and pricing |
Indoor/outdoor duplex
control/alarm system
120 VAC control/alarm circuit |
120 VAC or
120/208/240 VAC |
Up to 40 FLA |
Distance between
start & stop float |
Three or four Sensor Float® control
switches
(mounting clamp version) |
|
| |
| INTRINSICALLY
SAFE |
APPLICATION |
PUMP VOLTAGE RATING |
FULL LOAD AMPS |
PUMPING RANGE |
FLOATS INCLUDED |
|
Model 114 |
Single phase simplex control/alarm
system with intrinsically safe float circuits |
120 VAC or
120/208/240 VAC |
Up to 40 FLA |
Distance between
start & stop float |
Three Sensor Float® control switches |
|
Model 124 |
Single phase duplex alternating
control/alarm system with intrinsically safe float circuits |
120 VAC or
120/208/240 VAC |
Up to 40 FLA |
Distance between
start & stop float |
Three or four Sensor Float® control
switches |
|
Model 314 |
Three phase simplex control/alarm
system with intrinsically safe float circuits |
Consult Factory
for application
specifications |
Up to 25 FLA |
Distance between
start & stop float |
Three Sensor Float® control switches |
|
Model 324 |
Three phase duplex alternating
control/alarm system with intrinsically safe float circuits |
Consult Factory
for application
specifications |
Up to 25 FLA |
Distance between
start & stop float |
Three or four Sensor Float® control
switches |
|
| DRIP IRRIGATION |
APPLICATION |
PUMP VOLTAGE RATING |
FULL LOAD AMPS |
PUMPING RANGE |
FLOATS INCLUDED |
| Model IFS Drip |
Embedded controller based single phase simplex control/alarm system for subsurface drip irrigation |
120 or 230 VAC |
Up to 15 FLA |
Dependent on timer settings |
Four Sensor Float® control switches |
| Model DP |
PLC controller based single phase simplex control/alarm system for subsurface drip irrigation |
120 or 230 VAC |
Up to 3015 FLA |
Dependent on timer settings |
Four Sensor Float® control switches |
|
|
TIMED DOSING |
APPLICATION |
PUMP VOLTAGE RATING |
FULL LOAD AMPS |
PUMPING RANGE |
FLOATS INCLUDED |
|
Model TD |
Indoor/outdoor
single phase simplex control/alarm system. Timed dose pump switch
control. |
120 VAC or
120/208/240 VAC |
Up to 20 FLA |
Dependent on timer settings |
One SJE PumpMaster® pump switch and
one Sensor Float® Mini
control switch |
|
Model DTD |
Indoor/outdoor
single phase duplex control/alarm system. Timed dose pump switch
control. |
120 VAC or
120/208/240 VAC |
Up to 30 FLA |
Dependent on timer settings |
One SJE PumpMaster® pump switch and
one Sensor Float® Mini
control switch |
|
Model PS |
Indoor/outdoor single phase duplex
control/alarm system for pump chamber and
sandfilter timed dose control.
|
120 VAC or
120/208/240 VAC |
Up to 20 FLA |
Pump Chamber:
Dependent on timer settings & pump switch
Sandfilter Chamber:
.75" - 6.5" |
Two SJE PumpMaster® pump switches, one
SJE PumpMaster® SPDT pump switch and one Sensor Float®
control switch |
|
| |
| PLUGGER |
APPLICATION |
PUMP VOLTAGE RATING |
FULL LOAD AMPS |
PUMPING RANGE |
FLOATS INCLUDED |
|
Model RP |
Indoor/outdoor single phase simplex
control/alarm system. Plug in pump switch control. |
RP1 =
120 VAC
RP2 =
208/240 VAC |
120V up to 15 FLA
208/240V up to 12 FLA |
Dependent on pump switch |
One Sensor Float® control switch and
one pump switch
(mounting clamp version) |
|
JB Plugger |
Indoor/outdoor enclosure provides
convenient wiring connection for pump station applications. |
120/208/240 VAC |
Not applicable |
Distance between start & stop float or
range of pump switch |
Includes 120V or 208/240V receptacle
for pump, pump switch and terminal strip for alarm system connections |
|
PS Patrol® |
Built-in high water alarm provides
convenient location to connect wiring required for 120V or
208/240V pump station application. 9V model available. |
120/208/240 VAC |
Up to 15 FLA |
Dependent on pump switch |
Available with mercury or mechanical
pump switches and in various cord lengths |
|
| |
| WATER WELL |
APPLICATION |
PUMP VOLTAGE RATING |
FULL LOAD AMPS |
PUMPING RANGE |
FLOATS INCLUDED |
|
Model 126 |
Single phase duplex alternating water well pump
control. |
120/208/240 VAC |
Up to 30 FLA |
Dependent on pressure switch setting |
Not applicable |
|
| STARTER BOXES |
PHASE |
AC VOLTAGE |
FULL LOAD AMPS |
SB1 |
Single phase |
240 VAC |
32 |
SB2 |
Three phase |
240 VAC |
23-32 |
SB3 |
Three phase |
208/240/480 VAC |
23-32 |
|
|
SPECIAL APPLICATIONS |
DESCRIPTION |
|
VFDC-4000
Controller |
The VFDC-4000 controller is a microprocessor controlled system which controls up to four VFDs for constant pressure applications. The VFDC-4000 controller monitors the discharge pressure of a pumping system and adjusts the speed of each pump to maintain a constant pressure. The VFDC-4000 controller also features built-in data logging, communication capabilities, and automatic pump alternation functions. |
|
LevCon™ Controller |
The LevCon™ set point controller is a self-contained micro-processor controlled system capable of monitoring the level of the wet well and automatically controlling two pumps. It has 10 digital input channels, 1 analog input channel, and 6 relay output channels. The LevCon™ controller is equipped with a keypad and a 2 line by 16 character LCD display for level, pump status monitoring, and operation setup. UL/cUL Listed. |
| SP6R Level Controller |
Simple, easy-to-use microprocessor-based controller monitors any 4-20 mA signal. It has six programmable relay outputs that can be used for control and alarm. The transducer input zero and span are fully configurable. A simulation mode allows the user to test the set points and relay operation. Also available in a NEMA 4X enclosure. Call for details. |
| SP6R-LSC Lift Station Controller |
Simplicity at its best. This easy-to-use microprocessor-based controller monitors the level in the wet well via a submersible pressure transducer or any other device with a 4-20 mA signal output. The SP6R-LSC displays level set points, pump run time, pump cycle count and actual level. In addition, it provides pump alternation and has a simulation feature. It can be configured for pump down or pump up applications. Also available in a NEMA 4X enclosure. Call for details. |
Model LSC12 Panel or
Model LSC32 Panel |
Single phase or three phase, duplex, transducer based lift station control system for alternating pump control and system monitoring for water and sewage applications. Both models feature the SP6R-LSC lift station controller showcased above. |
Engineered Custom
Control Panels |
Built specifically for your application, whether a basic or state-of-the-art industrial grade control system. Please call or fax in your specifications for a quote. |
|
|
Liquid Level
ALARM SYSTEMS |
APPLICATION |
ENCLOSURE |
VOLTAGE |
OPTIONS |
Tank
Alert® AB |
Designed to monitor liquid levels in
lift pump chambers, sump pump basins, holding tanks, sewage, effluent filters and water system. |
NEMA 1
(indoor) |
120V 50/60 Hz or 9 VDC battery backup
(battery not included) |
Alternate float switches available |
Tank
Alert® ABP |
Designed to monitor liquid levels in
lift pump chambers, sump basins, holding tanks and water systems. |
NEMA 1
(indoor) |
120V 50/60 Hz
or 9 VDC battery backup
(battery not included) |
Two factory-spliced SJE MilliAmpMaster® control switches |
Tank
Alert® ABW |
Designed to monitor liquid levels in lift pump chambers, sump basins, holding tanks and water systems. |
NEMA 1
(indoor)
|
120V
60 Hz |
Alternate float switches available |
Tank
Alert® ABW
(UL Listed Component Version) |
Designed to monitor liquid levels in lift pump chambers, sump basins, holding tanks and water systems. |
NEMA 1
(indoor) UL Listed enclosure. |
120V
60 Hz |
Alternate float switches available |
Tank
Alert® I |
Designed to monitor liquid levels in lift pump chambers, sump basins, holding tanks and water systems. |
NEMA 1
(indoor) |
120V 50/60 Hz or
230V 50/60 Hz |
Alternate float switches available |
Tank
Alert® XT
(Includes Alarm Auto Reset) |
Designed to monitor liquid levels in lift pump chambers, sump basins, holding tanks and water systems. |
Meets Type 3R water-tight standard |
120V 50/60 Hz |
Alternate float switches available, alarm auxiliary contacts, terminal block, 6' power cord |
Tank
Alert® 4X
(Includes Alarm Auto Reset) |
Designed to monitor liquid levels in lift pump chambers, sump basins, holding tanks and water systems. |
NEMA 4
(indoor/outdoor) |
120V 50/60 Hz |
Alternate float switches available, alarm auxiliary
contacts |
|
| |
Wide-Angle
PUMP SWITCHES |
APPLICATION |
HP RATINGS |
START AMPS RUN AMPS |
PUMPING RANGE |
Junior Super Single®
(mercury activated) |
Provides automatic pump operation
in sump, sewage and non-potable
water applications. |
1/2 HP at 120V
1 HP at 230V |
40 (120V)/13
20 (230V)/8 |
6.5 to 19 inches |
Super Single®
(mercury activated) |
Provides automatic pump operation for
sump and sewage pumps, solenoids and relays. Not sensitive to
rotation/turbulence. |
1 HP at 120V
2 HP at 230V |
55 (120V)/15
35 (230V)/12 |
6.5 to 13.5 inches |
Double Float®
(mercury activated) |
Provides automatic pump operation for
sump and sewage pumps, solenoids and relays. Not sensitive to
rotation/turbulence. |
1 HP at 120V
2 HP at 230V |
55 (120V)/15
35 (230V)/12 |
1.75 to 48 inches
wider ranges available |
Double Float® Master
(mechanically activated) |
Provides automatic pump operation in
potable water and sewage applications. Not sensitive to
rotation/turbulence. |
N/A |
78/13 (120V or 240V) |
10 to 56 inches up to 6 feet available |
SJE PumpMaster®
(mechanically activated) |
Provides automatic pump operation in potable water and sewage applications. Not sensitive to rotation/turbulence. |
1/2 HP at 120V
1 HP at 230V |
85 (120V)/13
85 (230V)/13 |
7 to 36 inches |
SJE PumpMaster® Plus
(mechanically activated) |
Provides automatic pump operation in potable water and sewage applications. Not sensitive to rotation/turbulence. |
3/4 HP at 120V
2 HP at 230V |
85 (120V)/15
85 (230V)/15 |
7 to 36 inches |
SJE PumpMaster® SPDT
(mechanically activated) |
Can be wired to provide automatic pump up or pump down operation in potable water and sewage applications. |
1/2 HP at 120V
1 HP at 230V |
85 (120V)/13
85 (230V)/13 |
7 to 36 inches |
SJE AmpMaster®
(mechanically activated) |
Provides automatic control of grinder and high head sewage pumps. |
1 1/2 HP at 125V
3 HP at 250V |
120 (125V)/20
120 (250V)/20 |
9 to 24 inches |
SJE VerticalMaster®
(mechanically activated) |
Provides automatic pump operation
in confined areas. For water and
sump applications. |
1/2 HP at 120V
1 HP at 230V |
60 (120V)/13
60 (230V)/12 |
.75 to 6.5 inches |
SJE D-Master™
(pressure-actuated) |
Provides automatic pump operation
in confined areas. For
sump applications. |
1/2 HP at 120V
|
78/13
|
10 inches |
|
| |
Narrow-Angle
CONTROL SWITCHES |
APPLICATIONS |
CONTROL DIFFERENTIAL |
ELECTRICAL RATING |
MOUNTING OPTIONS |
Sensor Float®
(mercury activated) |
Activates alarms, control panels,
solenoids and relays. |
Approximately .5
inch above or
below horizontal |
5 amp
120V or 230V |
Mounting Clamp
Internal Weight
Cable Weight |
Sensor Float® Mini
(mercury activated) |
Activates alarms, control panels,
solenoids and relays. |
Approximately .5
inch above or
below horizontal |
5 amp
120V or 230V |
Mounting Clamp
Cable Weight |
SJE SignalMaster®
(mechanically activated) |
Activates alarms, control panels,
solenoids and relays. |
Approximately 1.5
inch above or
below horizontal |
5 amp
125V or 250V |
Mounting Clamp
Cable Weight |
SJE SignalMaster® SPDT
(mechanically activated) |
Activates alarms, control panels,
solenoids and relays. |
Approximately 1.5
inch above or
below horizontal |
5 amp
125V or 250V |
Mounting Clamp
Cable Weight |
SJE MilliAmpMaster™
(mechanically activated) |
Activates low current alarms, and control panels. |
45 degrees above or
below horizontal |
Down to 0.160mA at 125 VAC |
Mounting Clamp
Cable Weight |
|
| |
|
ACCESSORIES |
APPLICATION |
ENCLOSURE |
OPTIONS |
|
Junction Boxes |
Provides convenient location to
connect all wiring required for a typical pumping station, on-site
system or other electrical installations. |
NEMA 4X
(indoor/outdoor) |
Sizes include:
4" x 4" x 4",
6"x 6" x 4"
8" x 8" x 4" |
|
Cable Weight |
Provides an accurate pivot point for
suspended float switches. |
|
|
|
Cable Connectors |
Provides strain relief and a
liquid-tight seal
for electrical cable. |
|
Round or flat connectors available |
|
Hub Assembly |
Convenient connector for a conduit
run. |
|
1", 1.5" and 2" sizes
available |
|
Cord Seal |
Provides strain relief and a
liquid-tight seal. |
|
|
Cable Clamp
Assembly |
Secures cable in a vertical direction and provides cable anchor point and strain relief. |
|
For use with 18/16 gauge, 14 gauge, or 12 gauge cable |
| Float Bracket |
Provides a convenient location for securing both internally and externally weighted floats. |
|
Six or four float bracket available |
|